Access Guide
About
- The nearest University owned parking garage is the Prospect Avenue Garage.
- View information on Prospect Avenue Garage (opens new tab) .
- Dickinson Hall is a 4 story medium sized building.
- The building has 3 stairways, 1 of which has a stair lift. There is no elevator in this building.
- The floors are signed as Ground, first, second and third.
- Dickinson Hall is connected internally to McCosh Hall.
Getting Inside
- There is step-free access via slopes on the approach to Dickinson Hall.
- The building has 4 entrances.
Entry 1 has step-free level access and a push plate activated door (accessible entrance). - The entrances are signed Entry 1, Entry 2 and Entry 3. Entry 4 is not signed.
- Entry 1, Entry 2 and Entry 4 are used to access the first floor of the building.
Entry 3 is used to access the ground floor of the building and the restroom with adaptations.
Entry 3 has sloped access and a manual door.
Entry 2 and Entry 4 have stepped access and manual doors.
Getting Around
- There is not step-free access around Dickinson Hall unless using the stair lift.
The stair lift is located in the Entry 1 stairwell.
The stair lift runs between the ground, first and second floors. - There is not step-free access to the third floor, it can only be accessed by the Entry 4 stairway.
There are 5 rooms on the third floor accessed from the stairway lobby.
There are 5 steps leading to rooms 210 and 211 on the second floor.
An additional stair lift is available to overcome these steps. - There is internal access between Dickinson Hall and McCosh Hall on the first floor, via 4 steps.
- Floor surfaces along circulation routes are hard and smooth, with some having a shiny finish.
Suite 113 in Dickinson Hall has carpeted flooring. - There are resting areas in some circulation and lobby areas with a mixture of seating.
- Wayfinding signage and floor plans are provided in circulation routes and lobby areas.
Restrooms and Changing Facilities Available
- There is 1 restroom with adaptations.
- The restroom with adaptations is located at the end of the ground floor corridor.
- The restroom with adaptations has a right hand transfer space.
- Step-free female restrooms are located on the ground and first floors.
- Step-free male restrooms are located on the ground and second floors.
Entrance (Entry 1)
- This entrance is located at the side of the building, facing the University Chapel.
- This entrance gives access to a stairway with a stair lift.
- There is step-free access via ramp at the entrance.
- The ramp has a gradient easier than 1:20.
- The width of the ramp is 3ft 5in (105cm).
- The slope bypasses the step.
- There is 1 step.
- The height of the highest step is 6in (16cm).
- There is a key fob/card reader at a height of 2ft 10in (87cm).
- There is a single automatic door at this entrance.
- The door opens towards you.
- There is a push plate at a height of 2ft 4in (70cm).
- The width of the opening is 2ft 8in (82cm).
- The door has a high color contrast.
Stair Lift (Entry 1)
- The lift is located on the stairway immediately beyond Entry 1.
- The floors which are accessible by this lift are G, 1 and 2.
- The lift has a turning space of 2ft 6in x 4ft (76cm x 122cm) in front of it.
- The dimensions of the lift are 2ft 7in x 3ft 12in (80cm x 121cm).
- The lift is slow moving and the button needs to be pressed constantly when in use.
- There is a seat at a height of 1ft 7in (48cm) from the floor.
- Lighting levels are low.
Stairway (Entry 1)
- The floors which are accessible by stairway are G, 1 and 2.
- There are 20 steps between floors.
- There are handrails on both sides.
- The handrails cover all steps.
- The handrails extend horizontally beyond the first and last step.
- The height of the highest step is 7in (17cm).
- The minimum tread depth is 1ft 1in (32cm).
- Lighting levels are low.
Entrance (Entry 3)
- This entrance is located next to Washington Road.
- This entrance gives access to the ground floor.
- There is step-free access via a slope at the entrance.
- The ramp has a gradient of 1:11.
- There is a canopy or recess which provides weather protection at the entrance.
- There are double manual doors at this entrance.
- The doors open towards you.
- The doors require effort to open.
- The width of the opening is 4ft 7in (140cm).
- The doors have a high color contrast.
- There is a second manual door.
- The second door opens towards you.
- The second door requires effort to open.
- The width of the opening is 3ft 1in (95cm).
- There is a raised threshold at the opening.
- The second door has a high color contrast.
Restroom with Adaptations (Ground Floor - Right Hand Transfer - All Gender Restroom)
-
Location and Access
View
- The restroom surveyed is approximately 3yd 10in (3m) from the Entry 3 door.
- There is step-free level access into the restroom.
- There is Braille, tactile, pictorial and written text signage on or near the restroom door.
- The door into the restroom opens outwards and has a high color contrast.
- The door requires effort to open.
- The width of the restroom door opening is 2ft 9in (84cm).
- The door has a push button lock.
- Internally the door has a high color contrast.
-
Dimensions and Features
View
- The overall dimensions are 5ft 9in x 9ft 4in (176cm x 285cm).
- The turning space dimensions are 5ft 9in x 7ft 3in (176cm x 220cm).
- There is a lateral transfer space to the right of the WC as you look at it.
- The lateral transfer space is 3ft 10in (118cm) (from the side of the WC pan to the wall).
- There is a lever flush on the non-transfer side.
- There is a horizontal grab bar on the rear wall and on the side wall.
- The horizontal grab bars have a high color contrast with the surrounding walls.
- There is a vertical grab bar on the side wall.
- The vertical grab bar has a medium color contrast with the surrounding walls.
- The WC seat is 1ft 6in (46cm) from the floor.
- The WC seat has a low color contrast.
- There is a wall mounted toilet paper dispenser which can be reached when seated on the WC.
- The toilet paper dispenser has a high color contrast.
- The toilet paper dispenser is 1ft 7in (49cm) from the floor.
- The sink is 2ft 10in (87cm) from the floor.
- The sink faucet type is sensor.
- There is a wall mounted soap dispenser.
- The soap dispenser has a high color contrast.
- The soap dispenser is 3ft 8in (113cm) from the floor.
- There is a wall mounted paper towel dispenser.
- The paper towel dispenser has a high color contrast.
- The paper towel dispenser is 3ft 7in (110cm) from the floor.
- There is a mirror.
- The stall has a wastebasket.
- There are two coat hooks.
- The coat hooks are 3ft 11in and 5ft 11in (120cm and 180cm) from the floor.
- There is a varying color contrast between the walls and floor.
- Lighting levels are bright.