Skip to main content

Andlinger Center for Energy and the Environment - South Wing

86 Olden Street, Princeton University, Princeton, NJ, 08544

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

About

  • The nearest University owned parking garage is the Prospect Avenue Garage.
  • View information on Prospect Avenue Garage (opens new tab) .
  • Andlinger Center for Energy and the Environment - South Wing is a medium size building with 4 floors.
  • There is 1 elevator and 1 stairway within the building.
  • The floors are signed as level 0, 1B, 1L and 2.
  • There are entrances from Engineering Quadrangle E-Wing, Bowen Hall and Andlinger Center for Energy and the Environment - North Wing to this building.

Getting Inside

  • The approach to the building is step-free via slopes.
  • Andlinger Center for Energy and the Environment - South Wing has 4 entrances, 1 provides step-free sloped access (accessible entrance).
  • The accessible entrance gives direct access to the elevator on level 1L, which provides step-free level access to level 0, 1B and 2.
  • The external entrances to levels 0, 1L and 2 from the courtyard are stepped.
    The external entrance to 1B and internal entrances from Bowen Hall on 1B, E-Wing in the Engineering Quadrangle and the 2 external entrances on 1L are sloped.
    Internal entrances from Andlinger Center for Energy and the Environment - North Wing on level 2 and level 0 are step-free and level.

Getting Around

  • It is possible to overcome all steps once inside the building.
  • There is stepped access to level 1B from level 1L, these can be bypassed using the elevator.
  • There are step-free and level internal entrances from Andlinger Center for Energy and the Environment - North Wing on level 0 and level 2.
    There is a step-free entrance with a slope and a manual door to Bowen Hall on level 1B.
    There is an entrance to Engineering Quadrangle - E Wing on level 1L that is step-free with a slope.
  • Floor surfaces along all circulation routes are hard and smooth, apart from the seating area on level 0.
    The flooring is smooth stone which is not slippery.
  • There are resting areas in some circulation and lobby areas with a mixture of seating.
  • Wayfinding signage and floor plans are provided in circulation routes and lobby areas.

Restrooms and Changing Facilities Available

  • There are 4 restrooms with adaptations.
  • Restrooms with adaptations are located on the level 0 and level 2 corridors.
  • All restrooms with adaptations have a left hand transfer space.
  • Step-free male restrooms are located on the level 0 and level 2 corridors.
  • Step-free female restrooms are located on the level 0 and level 2 corridors.
  • Parent and baby changing facilities are located within the standard restrooms on level 0 and level 2.

Entrance (Accessible Entrance)

  • This entrance is located in the North Wing Andlinger building off Olden Street.
  • This entrance gives access to level 1 and the elevator.
  • There is step-free access via a slope at the entrance.
  • There is a canopy or recess which provides weather protection at the entrance.
  • There is a key fob/card reader at a height of 4ft 1in (124cm).
  • There are double automatic doors at this entrance.
  • The doors open towards you.
  • There is a push plate at a height of 3ft 6in (107cm).
  • The width of the opening is 5ft 1in (155cm).
  • The doors have a low color contrast.
  • There is a second set of automatic doors.
  • The second set of doors open towards you.
  • There is a push plate at a height of 2ft 9in (85cm).
  • The width of the opening is 5ft 1in (155cm).
  • The second doors have a low color contrast.

Elevator

  • The elevator is located in the level 1 lobby.
  • The floors which are accessible by this elevator are 0, 1B, 1L and 2.
  • The elevator has a turning space of 2ft 6in x 4ft (76cm x 122cm) in front of it.
  • The external elevator control buttons have tactile markings, Braille markings and a low color contrast.
  • The external elevator controls are at a height that can be easily reached.
  • The elevator door has a low color contrast.
  • The elevator door opening width is 3ft 6in (107cm).
  • The internal dimensions of the elevator are 5ft 9in x 7ft 10in (175cm x 240cm).
  • The internal elevator control buttons have tactile markings, Braille markings and a low color contrast.
  • The internal elevator controls are at a height that can be easily reached.
  • Internally the elevator has: a separate door to exit and a visual floor indicator.
  • Lighting levels are low within the elevator.

Stairway

  • The floors which are accessible by stairway are 0, 1B, 1L and 2.
  • There are 20+ steps between floors.
  • There are handrails on both sides.
  • The handrails cover all steps.
  • The handrails extend horizontally beyond the first and last step.
  • The height of the highest step is 7in (17cm).
  • The minimum tread depth is 12in (30cm).
  • Lighting levels are varied.

Restroom with Adaptations (Level 0 - Female - Left Hand Transfer)

  • Location and Access View
    • The restroom surveyed is approximately 41yd 1ft (38m) from the elevator.
    • There is step-free level access into the restroom.
    • There is Braille, tactile, pictorial and written text signage on or near the restroom door.
    • The door into the restroom opens inwards and has a low color contrast.
    • The door requires effort to open.
    • The width of the restroom door opening is 2ft 9in (83cm).
    • The door has a lever twist lock.
    • Internally the door has a medium color contrast.
  • Dimensions and Features View
    • The overall dimensions are 5ft x 9ft 6in (153cm x 290cm).
    • There is a lateral transfer space to the left of the WC as you look at it.
    • The lateral transfer space is 2ft 10in (86cm) (from the side of the WC pan to the wall).
    • There is a wall sensor flush for the WC.
    • There is a horizontal grab bar on the rear wall and on the side wall.
    • The horizontal grab bars have a high color contrast with the surrounding walls.
    • There is a vertical grab bar on the side wall.
    • The vertical grab bar has a high color contrast with the surrounding walls.
    • The WC seat is 1ft 5in (44cm) from the floor.
    • The WC seat has a low color contrast.
    • There is a wall mounted toilet paper dispenser which can be reached when seated on the WC.
    • The toilet paper dispenser has a high color contrast.
    • The toilet paper dispenser is 1ft 10in (56cm) from the floor.
    • The sink and faucets are located outside the stall.
    • The stall has a wastebasket.
    • There is one coat hook.
    • The coat hook is 4ft 7in (140cm) from the floor.
    • The baby changing station when in use is at a height of 2ft 9in (84cm) from the floor.
    • There is a high color contrast between the walls and floor.
    • Lighting levels are even.